Manufacturer: | SOEHNLE |
Model(s): | 7741-2-3 OLD |
Date updated: | 11.02.00 |
OLD TYPE 7741/2/3 - (Soehnle logo beneath On/Off/Tare button)
METRIC ONLY TYPE
1. Remove left hand end cap.
2. Adjust range with bottom trim pot
DUAL KILO/LB VERSION
1. Switch scale on and allow display to settle on zero.
2. Press key and hold down for approx. 15 seconds.
3. Release.
4. Display will show [CAL 0].
5. Apply full load of scale quickly so that display does not settle until full load is applied.
6. Remove weights and press button again.
7. Scale is now in normal weighing mode.
POUNDS/KILOS CONVERSION
1. Switch machine off.
2. Press button and hold.
3. Display will show [88888].
4. Release button and display will show either lb or kg.
5. Press button to switch from one to the other.
6. When display shows required units press button and hold for 15 seconds.
7. Release button and machine will be in normal weighing mode showing the unit selected.