CALIBRATION INSTRUCTIONS

Index of Calibration Instructions | Stringer Home Page


Manufacturer: SOEHNLE
Model(s): 7741-2-3 NEW
Date updated: 11.02.00

NEW TYPE 7741/2/3 - (Soehnle logo above On/Off/Tare button)

1. Switch on. Allow display to settle on zero.

2. Press and hold down button until display shows [ C 0] followed by [ C 100].

3. Place full capacity on platform. Press and release button again. Display will show [ 100 ].

4. Remove weights. Press and release button again. Machine reverts to weighing mode.

5. Check calibration throughout the range.

POUNDS/KILOS CONVERSION

1. Switch machine off.

2. Press button and hold.

3. Display will show [88888].

4. After approx 5 seconds display will show either lb or kg.

5. Press button to switch from one to the other.

6. When display shows required units press button and hold for approx 5 seconds.

7. Display shows [ 8888] then reverts to weighing mode in the units selected.